94
• Technology:
- Pressure range from 0.10 bar to 11 bar
- Resolution of 0.01 bar
- Operating temperature: -25°C to +60°C
- Easy to read thanks to the 12-mm high figures, last, smallest digit displayed
- Visual checking of the correct functioning of digits on each pressurisation
- Product available in different measuring units (bar, psi*, kPa*)
- Gauge turns on when pressurised (connection to the valve)
- Turns off automatically when pressure is withdrawn or with constant pressure
for over 10 seconds
- Duration of battery lifetime: 10 years after manufacture in temperate environment
(the battery is non-replaceable)
- Automatic recalibration to zero on each inflation for zero measurement deviation
- Air pressure measurements displayed when the buttons are released
- User alert in the event of a fault
ELECTRONIC INFLATING GAUGEWITH HANDLE
graduated from 0.10 to 11 bar
for inflating and checking of pressure
AIR OR NITROGEN USE
Compliant to standard EN12645, NFR 63-302.
Digital display –High performance of lowpressure accuracy evenwithH.V.Gapplications
P/N suffix: -00 or -67 = per unit
• Design - Strength:
- Proven design of Univ’Air and Eurodainu inflating gauges
- Air inlet connector F G 1/4
- Rubber protector around the measuring system.
- Watertight performance reinforced with a transparent dial
- Very high measuring accuracy with this level of accuracy maintained in the event
of an impact on the device
Strength: high technology plastic components.
- Safety handle
- Corrosion resistant internal mechanism.
- Air filtered in the indicator mechanism by stainless steel and nickel silver micro-porous filter
- Device resistant to accidental high pressure of 15 bar
39766-67
65088-67
65089-67
Intermediate-sized quick coupler for inflating gauges
with a G 1/4 air inlet coupler
Teflon-coated threaded quick
coupler G 1/4
Grooved junction coupler for hose
ø int. 6 - 7 mm conical threaded G 1/4
* Sold for export only and according to local regulations.
Graduation
7 x 13 mm hose
Air inlet side
coupler
Use
L (m)
Hose P/N
39900-00
0,10 to 11 bar
1,5
39064-00
F-G 1/4
39901-00
1,4 to 160 psi *
1,5
39064-00
F-G 1/4
39902-00
10 kPa to 1100 kPa *
1,5
39064-00
F-G 1/4